MS5203 Insulation Resistance Multimeter vs FLUKE F1520
Only US$ 179.98,rigol ds, -MS5203 Insulation Resistance Multimeter vs FLUKE F1520 - from iboxall with free shipping now.
New MASTECH MS5203 insulation resistance tester Multimeter up to 1000V Compared with FLUKE F1520 up to 10G ohm
Brand new with 1 year USA warranty, 14 days return policy
Complies with IEC/EN 61010-1 1000V CAT III 600 V CAT IV
http://www.iboxall.com/ms5203-insulation-resistance-multimeter-vs-fluke-f1520
Features
INSULATION VOLTAGE:50V,100V,250V,500V,1000V
INSULATION RESISTANCE 0.01MΩ~10GΩ
AUTO CACULATE PI AND DAR
STORE/LOAD FUNCTION
COMPARE FUNCTION
LIVE VOLTAGE DETECT
AUTO DISCHARGE FOR CAPACITIVE LOAD
TIMER FUNCTION FOR INSULATION TEST
DCV AND ACV TEST
CONTINUITY TEST
AUTO POWER-OFF
BATTERY CHECK
Specifications
FUNCTION RANGE ACCURACY
INSULATION OUTPUT VOLTAGE: 50V(0%~+20%) 0.01MΩ~50MΩ ±3%
OUTPUT VOLTAGE: 100V(0%~+20%) 0.01MΩ~100MΩ ±3%
OUTPUT VOLTAGE: 250V(0%~+20%) 0.01MΩ~250MΩ ±3%
OUTPUT VOLTAGE: 500V(0%~+20%) 0.01MΩ~500MΩ ±3%
OUTPUT VOLTAGE: 1000V(0%~+20%) 0.01MΩ~2000MΩ ±3%
2.0GΩ~10GΩ ±10%
DCV INPUT IMPEDANCE:10MΩ 0.1V~1000V ±0.5%
ACV INPUT IMPEDANCE:10MΩ 0.1V~750V ±1%
CONTINUITY TEST CURRENT: 10mA 0.001Ω~200.0Ω ±0.5%
Specifications
l Complies with IEC/EN 61010-1 1000V CAT III 600 V CAT IV.
l 1000V DC Voltage,750V AC Voltage.
l when the input terminals is Hi and Lo , The overload protective voltage is 600V. When the input terminals is V and COM, the overload protective voltage is 1200 V under the voltage test; in other test mode ,the overload protective voltage is 250V.
l Batteries:Six AA batteries (NEDA 15A or IEC LR6)Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
l Insulation Measurement Range : 0.01 MΩ to 10,code standard resistor.00 GΩ.
l Insulation Test Voltages : 50, 100, 250, 500, 1000 V .
l Insulation Source Voltage: + 20 %, - 0 %.
l Insulation Short-Circuit Test Current : 1 .8mA nominal.
l Insulation Auto Discharge : Discharge time <2 second for C = 1 μF or less.
l Insulation Live Circuit Detection : Inhibit test if terminal voltage > 20 V prior to initialization of test.
l Insulation Maximum Capacitive Load: Operable with up to 1 μF load.
l Storage Temperature : -40 °C to 60 °C.
l Operating Temperature: 0°C to 40 °C .
l Storage Altitude: 12000m
l Operating Altitude: 2000m 1000V CAT III,3000m 1000V Ⅱ
l Temperature Coefficient: 0.05 × (specified accuracy) per °C for temperatures < 18 °C or > 28 °C.
l Relative Humidity: 40%~75%(40%~60% when insulation test >1 GΩ)
l Size: 180(L) mm×140(W) mm× 65(H)mm.
Weight: approx 900g.(not including battery
Accuracy
DCV
RANGE
RESOLUTION
ACCURACY
200V
0.1V
±(0.5% +5)
1000V
1V
±(0.5%+5)
ACV
RANGE
RESOLUTION
ACCURACY (50~60Hz)
200V
0.1V
±(1.5%+5)
750V
1V
±(1.5%+5)
Resistance
RANGE
RESOLUTION
ACCURACY
20Ω
0.01Ω
±(1% +5)
200Ω
0.1Ω
±(1%+5)
Insulation
OUTPUT VOLTAGE
RANGE
RESOLUTIOIN
TEST CURRENT
ACCURACY
50V(0~20%) 0~20MΩ 0.01 MΩ
1mA@50K
±(3%+5)
20~50MΩ 0.1 MΩ
100V(0~20%) 0~20MΩ 0.01 MΩ
1mA@100K
±(3%+5)
20~100MΩ 0.1 MΩ
250V(0~20%) 0~20MΩ 0.01 MΩ
1mA@250K
±(3%+5)
20~200MΩ 0.1MΩ
200~250MΩ 1MΩ
500V(0~20%) 0~20MΩ 0.01 MΩ
1mA@500K
±(3%+5)
20~200MΩ 0.1MΩ
200~500MΩ 1MΩ
1000V(0~20%) 0~200MΩ 0.1 MΩ
1mA@1000K
±(3%+5)
200~1000MΩ 1 MΩ
1.00~5.00GΩ 0.01 GΩ
±(5%+0.1 GΩ)
5.00~10.00GΩ 0.01 GΩ
±(10%+0.2GΩ)
Accessories:
1) A pair of high-quality test leads for high volatge insulation ( red + black):
2) A pair of Clips (red + black);
3) Carrying bag: